Huaiyin Power Plant is a 1,760MW coal fired power project. It is located in Jiangsu, China. According to GlobalData, who tracks and profiles over 170,000 power plants worldwide, the project is currently active. It has been developed in multiple phases. Post completion of construction, the project got commissioned in November 1993. Buy the profile here.
Description
The project is currently owned by Huaneng Power International with a stake of 63.64%, Jiangsu Power Development and Jiangsu Yueda Investment.
It is a Steam Turbine power plant that is used for Baseload. The fuel is procured from Anhui Province, Henan Province and Shanxi Province.
Development status
The project got commissioned in November 1993.
Power purchase agreement
The power generated from the project is sold to State Grid Jiangsu Electric Power under a power purchase agreement.
Contractors involved
Huaiyin Power Plant (Huaiyin Power Plant Phase I & II Unit I) is equipped with Beijing Beizhong Steam Turbine Generator N220-12.7 / 535/535 steam turbine. The phase consists of 1 steam turbine with 220MW nameplate capacity.
Huaiyin Power Plant (Huaiyin Power Plant Phase I & II Unit II) is equipped with Beijing Beizhong Steam Turbine Generator N220-12.7 / 535/535 steam turbine. The phase consists of 1 steam turbine with 220MW nameplate capacity.
Huaiyin Power Plant (Huaiyin Power Plant Phase I & II Unit III) is equipped with Beijing Beizhong Steam Turbine Generator N330-17.75 / 540/540 steam turbine. The phase consists of 1 steam turbine with 330MW nameplate capacity.
Huaiyin Power Plant (Huaiyin Power Plant Phase I & II Unit IV) is equipped with Beijing Beizhong Steam Turbine Generator N330-17.75 / 540/540 steam turbine. The phase consists of 1 steam turbine with 330MW nameplate capacity.
Huaiyin Power Plant (Huaiyin Power Plant Phase III Unit I) is equipped with Beijing Beizhong Steam Turbine Generator N330-17.75 / 540/540 steam turbine. The phase consists of 1 steam turbine with 330MW nameplate capacity.
Huaiyin Power Plant (Huaiyin Power Plant Phase III Unit II) is equipped with Beijing Beizhong Steam Turbine Generator N330-17.75 / 540/540 steam turbine. The phase consists of 1 steam turbine with 330MW nameplate capacity.
Beijing Beizhong Steam Turbine Generator supplied QFSN 220-2 electric generator for the Huaiyin Power Plant (Huaiyin Power Plant Phase I & II Unit I).
Beijing Beizhong Steam Turbine Generator supplied QFSN 220-2 electric generator for the Huaiyin Power Plant (Huaiyin Power Plant Phase I & II Unit I).
Beijing Beizhong Steam Turbine Generator supplied QFSN 220-2 electric generator for the Huaiyin Power Plant (Huaiyin Power Plant Phase I & II Unit I).
Beijing Beizhong Steam Turbine Generator supplied QFSN 220-2 electric generator for the Huaiyin Power Plant (Huaiyin Power Plant Phase I & II Unit II).
Beijing Beizhong Steam Turbine Generator supplied QFSN 220-2 electric generator for the Huaiyin Power Plant (Huaiyin Power Plant Phase I & II Unit II).
Beijing Beizhong Steam Turbine Generator supplied QFSN 220-2 electric generator for the Huaiyin Power Plant (Huaiyin Power Plant Phase I & II Unit II).
Beijing Beizhong Steam Turbine Generator supplied QFSN 330-2 electric generator for the Huaiyin Power Plant (Huaiyin Power Plant Phase I & II Unit III).
Beijing Beizhong Steam Turbine Generator supplied QFSN 330-2 electric generator for the Huaiyin Power Plant (Huaiyin Power Plant Phase I & II Unit III).
Beijing Beizhong Steam Turbine Generator supplied QFSN 330-2 electric generator for the Huaiyin Power Plant (Huaiyin Power Plant Phase I & II Unit III).
Beijing Beizhong Steam Turbine Generator supplied QFSN 330-2 electric generator for the Huaiyin Power Plant (Huaiyin Power Plant Phase I & II Unit IV).
Beijing Beizhong Steam Turbine Generator supplied QFSN 330-2 electric generator for the Huaiyin Power Plant (Huaiyin Power Plant Phase I & II Unit IV).
Beijing Beizhong Steam Turbine Generator supplied QFSN 330-2 electric generator for the Huaiyin Power Plant (Huaiyin Power Plant Phase I & II Unit IV).
Beijing Beizhong Steam Turbine Generator supplied QFSN 330-2 electric generator for the Huaiyin Power Plant (Huaiyin Power Plant Phase III Unit I).
Beijing Beizhong Steam Turbine Generator supplied QFSN 330-2 electric generator for the Huaiyin Power Plant (Huaiyin Power Plant Phase III Unit I).
Beijing Beizhong Steam Turbine Generator supplied QFSN 330-2 electric generator for the Huaiyin Power Plant (Huaiyin Power Plant Phase III Unit I).
Beijing Beizhong Steam Turbine Generator supplied QFSN 330-2 electric generator for the Huaiyin Power Plant (Huaiyin Power Plant Phase III Unit II).
Beijing Beizhong Steam Turbine Generator supplied QFSN 330-2 electric generator for the Huaiyin Power Plant (Huaiyin Power Plant Phase III Unit II).
Beijing Beizhong Steam Turbine Generator supplied QFSN 330-2 electric generator for the Huaiyin Power Plant (Huaiyin Power Plant Phase III Unit II).
Harbin Boiler supplied steam boiler for the Huaiyin Power Plant (Huaiyin Power Plant Phase I & II Unit I).
Harbin Boiler supplied steam boiler for the Huaiyin Power Plant (Huaiyin Power Plant Phase I & II Unit I).
Harbin Boiler supplied steam boiler for the Huaiyin Power Plant (Huaiyin Power Plant Phase I & II Unit I).
Harbin Boiler supplied steam boiler for the Huaiyin Power Plant (Huaiyin Power Plant Phase I & II Unit II).
Harbin Boiler supplied steam boiler for the Huaiyin Power Plant (Huaiyin Power Plant Phase I & II Unit II).
Harbin Boiler supplied steam boiler for the Huaiyin Power Plant (Huaiyin Power Plant Phase I & II Unit II).
Harbin Boiler supplied steam boiler for the Huaiyin Power Plant (Huaiyin Power Plant Phase I & II Unit III).
Harbin Boiler supplied steam boiler for the Huaiyin Power Plant (Huaiyin Power Plant Phase I & II Unit III).
Harbin Boiler supplied steam boiler for the Huaiyin Power Plant (Huaiyin Power Plant Phase I & II Unit III).
Harbin Boiler supplied steam boiler for the Huaiyin Power Plant (Huaiyin Power Plant Phase I & II Unit IV).
Harbin Boiler supplied steam boiler for the Huaiyin Power Plant (Huaiyin Power Plant Phase I & II Unit IV).
Harbin Boiler supplied steam boiler for the Huaiyin Power Plant (Huaiyin Power Plant Phase I & II Unit IV).
Harbin Boiler supplied steam boiler for the Huaiyin Power Plant (Huaiyin Power Plant Phase III Unit I).
Harbin Boiler supplied steam boiler for the Huaiyin Power Plant (Huaiyin Power Plant Phase III Unit I).
Harbin Boiler supplied steam boiler for the Huaiyin Power Plant (Huaiyin Power Plant Phase III Unit I).
Harbin Boiler supplied steam boiler for the Huaiyin Power Plant (Huaiyin Power Plant Phase III Unit II).
Harbin Boiler supplied steam boiler for the Huaiyin Power Plant (Huaiyin Power Plant Phase III Unit II).
Harbin Boiler supplied steam boiler for the Huaiyin Power Plant (Huaiyin Power Plant Phase III Unit II).